Home › Guides › WV Class C Tester Exam Topics

Guide · West Virginia WVDEP · Class C Tester

What's on the WV Class C Tester exam

The Class C Tester exam is a written, multiple-choice test drawn from the testing standards, federal and state rules, and WVDEP's own forms. Here's what it covers, document by document, and how to study it.

80% to pass$75 exam fee3 attempts in 12 months
80%
Score needed to pass
$75
Exam fee, nonrefundable
$35
Each retest in the same year
10
Tightness tests to qualify

What a Class C certificate lets you do

Under WV Title 33, Series 30 (33CSR30) Section 3.3.c, a Class C certificate lets you perform tank or piping tightness testing, make minor repairs, and disconnect and reconnect piping and equipment on a UST system as needed to run the test. In West Virginia that's the Class C Tester. It's a separate certificate from Class A (installation) and Class B (closure).

Who can sit for it

33CSR30 Section 3.4 sets the requirements:

  • Active participation in at least 10 regulated UST tightness testing events conducted after December 22, 1988, with a list of the work, the site locations and the companies you did it for.
  • Proof of a current manufacturer certification for each tank or piping tightness test method you'll use, plus a signed statement that you'll follow the manufacturer's current protocol and WVDEP policy.
  • Written statements from two personal and two business references about your ethical practice.
  • You apply as an individual. Companies can't be certified, and you don't have to live in West Virginia.

The exam format

33CSR30 Section 3.4.g says the exams are written and multiple choice, with questions drawn from standards, instructions, industry recommended practices, and state and federal rules. You need to answer at least 80 percent correctly. You pay a nonrefundable $75 by check or money order at the exam and $35 for each retest in the same year. You can take it no more than three times in 12 months, and your application stays current for one year.

The WV Class C UST Study Guide, prepared by Marshall University CEGAS for WVDEP (January 2013 edition), describes the exam as open book. Confirm the current rules with WVDEP before you count on bringing books. Even on an open-book test, you won't have time to look everything up, so know where things are.

The documents the questions come from

That study guide groups its questions by source document. These are the primary documents:

  1. PEI RP1200: testing and verification of spill, overfill, leak detection and secondary containment equipment.
  2. 40 CFR Part 280: the federal UST technical standards.
  3. WV Title 33, Series 30: West Virginia's UST rule.
  4. WVDEP Miscellaneous Testing Report Form.
  5. WVDEP Documentation of Tightness Test Results policy.
  6. OSHA 1910.147: lockout/tagout.
  7. OSHA 1910.146: permit-required confined spaces.

The secondary documents are PEI RP100, NFPA 30 and 30A, and three manufacturer manuals on testing line leak detectors (Red Jacket, FE Petro/Franklin Fueling and Veeder-Root).

PEI RP1200: the biggest piece

Expect a lot of questions on how each piece of equipment is tested and what counts as a pass. The study guide works through secondary containment integrity testing on tanks and piping, hydrostatic and vacuum tests on spill buckets, containment sump tests, overfill devices (automatic shutoffs, ball floats and alarms), interstitial sensors (including discriminating vs non-discriminating), mechanical and electronic line leak detectors, shear valves and emergency stop switches. For each one, know the test method, how long the test runs and the pass/fail criteria.

40 CFR 280: the federal numbers

The federal rule supplies a handful of numbers that come up again and again. Under 40 CFR 280.20, overfill prevention has to shut off flow when the tank is no more than 95 percent full, or alert the driver at no more than 90 percent. Under 40 CFR 280.44, an automatic line leak detector has to catch a leak of 3 gallons per hour at 10 psi line pressure within 1 hour and gets an annual operation test, while a line tightness test has to detect 0.1 gallon per hour at 1½ times operating pressure. Know the definitions in 280.12 too. The study guide asks what counts as a regulated substance, a repair, and whether the term UST includes the connected underground piping.

WVDEP forms and policy: where WV is stricter

This is the part out-of-state testers miss. The WVDEP Miscellaneous Testing Report Form says that when you pressure or vacuum test, any loss of pressure or vacuum is a failed test, regardless of the manufacturer's pass criteria. The form also has to be completed and given to the owner or operator within 30 days of the test.

The same form gives a default hydrostatic sump test if you aren't using one of the listed methods: fill to at least 6 inches above the highest penetration, let it stand at least 15 minutes, test for at least 1 hour, and a level change of 1/8 inch or more is a failure.

WVDEP's Documentation of Tightness Test Results policy lists what every test report has to include: your manufacturer certification with its dates, the equipment make and model, facility identifiers, a site sketch, start and end times, the data collected, the pass/fail threshold, the result, and your signed statement that you followed the manufacturer's protocol. Tank, piping and line leak detector tests each add their own items. WVDEP uses manufacturer protocols as the yardstick for enforcement.

33CSR30 and safety

Expect questions on the certification rule itself: who qualifies, fees, attempts, expiration and renewal. Every certificate expires December 31 of every second year, and when you renew, a Class C Tester has to submit current manufacturer certifications for each test method (33CSR30 Section 3.5). The two OSHA standards cover lockout/tagout before you open a system and the rules for entering a permit-required confined space.

How the FuelCert Class C bank breaks down

  • PEI RP1200: spill buckets, sumps, overfill, ATGs, sensors, leak detectors, shear valves, E-stops31 Q
  • 40 CFR Part 280: release detection, walkthroughs, records and reporting24 Q
  • OSHA 1910.147: lockout/tagout10 Q
  • OSHA 1910.146: permit-required confined spaces10 Q
  • WV 33CSR30: certification rules9 Q
  • WVDEP Miscellaneous Testing Report Form8 Q
  • NFPA 30 and 30A: tightness test methods and pressures6 Q
  • WVDEP Documentation of Tightness Test Results policy5 Q
  • PEI RP100: test-related installation items3 Q

Study plan

A three-week Class C plan

  1. Before you start: the paperwork. List your 10 tightness tests, make sure every manufacturer certification is current, and ask your four references for their letters.
  2. Week 1: PEI RP1200. Go equipment by equipment: spill buckets, sumps, overfill, sensors, line leak detectors, shear valves, E-stops. For each one, write down the method, the duration and the pass criteria.
  3. Week 2: The rules. 40 CFR 280 definitions and leak detection numbers, then 33CSR30 Section 3, then the WVDEP report form and documentation policy. Memorize the “any loss is a fail” rule and the sump test numbers.
  4. Week 3: Safety and review. OSHA lockout/tagout and confined spaces, then mixed practice across all of it. Work toward scoring well above 80 percent before you test.

Studying for Class C?

106 Class C Tester questions and 56 flashcards, each with the document and section it came from. Try 7 free.

Open the West Virginia app

Running a testing crew?

Team plans start at $124.99/mo for 5 techs, so the whole crew studies from the same material.

See team plans

FAQ

WV Class C Tester exam questions

What score do I need to pass the WV Class C Tester exam?
You must correctly answer at least 80 percent of the questions in the category (33CSR30 Section 3.4.g.3). Maryland, by comparison, requires 90 percent.
Is the WV Class C exam open book?
The WV Class C UST Study Guide prepared for WVDEP (January 2013 edition) describes the exam as open book and multiple choice. Confirm the current rules with WVDEP before test day.
What experience do I need for Class C?
Active participation in at least 10 regulated UST tightness testing events conducted after December 22, 1988, plus proof of a current manufacturer certification for each tank or piping tightness test method you will use (33CSR30 Sections 3.4.d and 3.4.d.2).
Does a test pass if the manufacturer says it passed?
Not in West Virginia if you lost pressure or vacuum. The WVDEP Miscellaneous Testing Report Form says any loss in pressure or vacuum during the test is a failed test, regardless of the manufacturer's criteria.
How much does the exam cost and how many tries do I get?
A nonrefundable $75 by check or money order at the exam, and $35 for each retest within the same year. You can take the exam no more than three times in 12 months (33CSR30 Sections 3.4.g.4 and 3.4.h).
Are FuelCert questions the real exam questions?
No. FuelCert questions are original study material written from the same regulations and standards. They are not actual exam questions, and FuelCert is not affiliated with WVDEP.

Next step

Practice the Class C material

106 Class C Tester questions and 56 flashcards in the West Virginia app. Try 7 free, no credit card.

FuelCert Solutions is an independent study tool. It is not affiliated with, endorsed by, or approved by MDE or WVDEP, and our practice questions are not actual exam questions.