Tightness testing, sump and spill bucket tests, leak detectors and the WVDEP paperwork. Practice the Class C Tester material with questions that cite the exact section they come from.
106 practice questions56 flashcards7 free questions, no card
The exam at a glance
What you're walking into
80%
Score needed to pass
$75
Exam fee, nonrefundable
$35
Each retest in the same year
3
Max attempts in 12 months
Source: WV Title 33, Series 30 (33CSR30), Section 3.4. The exam is a written, multiple-choice test. Fees are paid by check or money order at the time of the exam. Applications stay current for one year from the date WVDEP receives them.
What the exam covers
What the Class C bank covers
The 106 Class C questions are drawn from these documents. Each one shows the exact section it came from.
WV 33CSR30: certification rules for Class C Testers9 Q
WVDEP Miscellaneous Testing Report Form8 Q
NFPA 30 and 30A: tightness test methods and pressures6 Q
WVDEP Documentation of Tightness Test Results Policy5 Q
PEI RP100: test-related installation items3 Q
Who can apply for Class C
Active participation in at least 10 regulated UST tightness testing events (conducted after December 22, 1988).
Proof of a current manufacturer certification for each tank or piping tightness test method you will use, plus a signed statement that you will follow the manufacturer's protocol and WVDEP policy.
Written statements from two personal and two business references. Certification goes to individuals, not companies, and you don't have to live in West Virginia.
Certificates expire December 31 of every second year.
Source: WV Title 33, Series 30 (33CSR30), Sections 3.4 and 3.5.
Try it
Sample questions from the app
These are copied straight from the West Virginia Class C Tester question bank. Pick your answer, then tap Show answer. Every question in the app shows its explanation and the source it came from.
Sample 1 of 5·Failed Test Criteria
According to the WVDEP Miscellaneous Testing Report Form, how much pressure or vacuum loss during a test results in a failed test?
AMore than 0.5 inches of mercury loss
BMore than 1 inch of mercury loss
CAny loss in pressure or vacuumCorrect
DLoss exceeding 10% of initial reading
Answer: C. The WVDEP Miscellaneous Testing Report Form states that any loss in pressure or vacuum occurring during the test results in a failed test, regardless of manufacturer criteria. Source: WVDEP Miscellaneous Testing Report Form
Sample 2 of 5·Spill Bucket Pass Criteria
According to PEI RP1200, what determines if a spill bucket passes the hydrostatic integrity test?
ANo measurable drop in water level during the test periodCorrect
BWater level drop of less than 1/8 inch
CWater level drop of less than 1/4 inch
DWater level drop of less than 1 inch
Answer: A. PEI RP1200 Section 6.2.6 states that a spill bucket passes the hydrostatic integrity test when there is no measurable drop in water level during the test period. Source: PEI RP1200 · Section 6.2.6
Sample 3 of 5·Mechanical LLD Test Rate
According to PEI RP1200, when testing a mechanical line leak detector with the STP on and full pump pressure indicated, what leak rate should the test apparatus orifice achieve?
A1 gallon per hour
B3 gallons per hourCorrect
C5 gallons per hour
D10 gallons per hour
Answer: B. PEI RP1200 Section 9.1.6 states the test apparatus leak orifice should be adjusted to achieve a 3 gallon per hour leak rate when the STP is on and full pump pressure is indicated. Source: PEI RP1200 · Section 9.1.6
Sample 4 of 5·Class C Experience Requirement
To be considered for a Class C certification, an applicant must demonstrate work experience by active participation in how many tank tightness tests?
A5 tests
B10 testsCorrect
C15 tests
D20 tests
Answer: B. WV Title 33 Series 30 Section 33-30.3.4.d requires that Class C applicants demonstrate active participation in at least 10 regulated UST tightness testing events. Source: WV Title 33, Series 30 (33CSR30) · Section 33-30.3.4.d
Sample 5 of 5·Completion Deadline
According to the WVDEP Miscellaneous Testing Report Form, within how many days of the test date must the applicable portions be completed and provided to the facility owner/operator?
A7 days
B14 days
C30 daysCorrect
D45 days
Answer: C. The WVDEP Miscellaneous Testing Report Form introduction states that applicable portions must be completed and provided to the facility owner/operator within 30 days of the test date. Source: WVDEP Miscellaneous Testing Report Form
What's in the app
Everything for the Class C test in one app
106 Class C questions
Every question shows an explanation and the document and section it came from.
56 flashcards
The test pressures, durations and pass/fail criteria, with the source on the back of every card.
AI tutor from the regs
Ask about test pressures, pass/fail criteria or line leak detectors. The tutor answers from the actual WV source documents.
All four WV classes
The West Virginia app also covers Class A Installer, Class B Closure and Class F Repair Tech: 395 questions in all.
Phone, tablet or computer
Opens in your browser and installs to your home screen. No app store, nothing to download.
Built by a fueling tech
Written by Trae Dodson, who has 30+ years of fueling equipment install and repair behind him.
✓
Pass guarantee
Study with us. Pass, or the next month is on us.
If you don't pass, email us your score report and we'll add a free month. It applies to subscriptions and the Exam Pass. Send it to info@fuelcertsolutions.net.
Pricing
Start free. Pay only if it's working.
7 free practice questions, no credit card. When you're ready, pick how you want to pay for the West Virginia app.
Exam Pass
$69.99one time
90 days of full access to the West Virginia app. Doesn't renew.
Individual monthly
$29.99/mo
Full access while you study. Cancel when you've passed.
Individual yearly
$134.99/yr
A full year of access, about $11.25 a month.
Got a crew to certify? Team plans start at $124.99/mo for 5 techs.
FAQ
WV Class C Tester exam questions
What score do I need to pass the WV Class C Tester exam?
You must correctly answer at least 80 percent of the questions in the category (33CSR30, Section 3.4.g.3). That's different from Maryland, which requires 90 percent.
How much does the WVDEP exam cost?
Applicants for Class A, B or C certification pay a nonrefundable $75 fee by check or money order at the time of the exam, and $35 for each retest within the same year (33CSR30, Section 3.4.h).
How many times can I take the exam?
No more than three times within a 12-month period. Applications stay current for one year from the date WVDEP receives them; after that you file a new application and pay the exam fee again (33CSR30, Section 3.4.g.4).
What experience do I need for Class C?
Active participation in at least 10 regulated UST tightness testing events, plus proof of a current manufacturer certification for each tank or piping tightness test method you will use (33CSR30, Sections 3.4.d and 3.4.d.2).
Can my company hold the Class C certification?
No. WV certifies individuals only; businesses and corporations can't be certified. You also don't have to be a West Virginia resident (33CSR30, Sections 3.4.a and 3.4.b).
Are these the real exam questions?
No. FuelCert questions are original study material written from the same regulations and standards the exam is based on. They are not actual examination questions, and FuelCert is not affiliated with MDE or WVDEP.
How much does it cost?
You can try 7 questions free with no credit card. Full access is $29.99/mo or $134.99/yr, or a one-time $69.99 Exam Pass that gives you 90 days of full access to one state's app and does not renew.
What is the pass guarantee?
If you don't pass, email us your score report and we'll add a free month. It applies to subscriptions and the Exam Pass.
Pass the Class C test
Start with 7 free questions. No credit card, nothing to install.